[Company Logo Image]

Home Up Feedback Order Quote Search

Kwip-Op Specs

[Under Construction]

Home
Up
Kwip-Op Specs
Kwip-Op Features

Specifications for
DOOR DYNAMICS "KWIK-OP"TM
Automatic Openers, Pneumatic for Swinging Doors

Basic Model includes:

Control Box that controls functions,
Openers to open doors, and
Closers to close doors.
For New or Retro fits.

APPLICATION
The DD-1000 & 2000 series door operator is a surface mounted pneumatic door opener for swing doors in handicap, institutional, commercial, and industrial applications. It is compatible with interior and exterior doors of virtually all types. Door panels for 2'0" to 5'0" wide and weighing up to 600 pounds can be accommodated. One way, two way, and two way bi-parting traffic patterns can be used by varying combinations of activators and orientations of activators. Simultaneous operation of double doors is standard.

DESCRIPTION
The DD-1000 & 2000 series operator applies a linear opening force to the door by a pneumatic cylinder, actuator arm, and a rubber wheel. No wear plate is necessary. There are only three bearing points of minimal wear. The operator is not attached to the door, consequently the door can be operated manually as a conventional door, or automatically through any desired system of control. The unit is virtually noiseless when operating. Door closers are included.

MOUNTING
The DD-1000 & 2000 series operator can be easily mounted to any conventional door frame head. The unit can be mounted on a flush ceiling application, since it does not require any clearance above the door frame opening.

OPERATION
Automatic door operation is accomplished when the open command is transmitted from wall switches, floor mats, motion or proximity sensors, security or other devices. The opening speed (1.5 to 5 seconds) is controlled by an air pressure regulator. The back check, closing speed, and latch check are controlled by the action of a LCN door closer. A (hold open time) microprocessor controls the time between the opening and closing functions, and is adjustable from 1 to 99 seconds of delay. This is the only electronic control in the unit.

CONTROL BOX
The control unit is designed for a permanent connection to a 11 5vac 50/60hz power source, which power the 24vac command signal controls, and air solenoid appropriate for the installation. The control unit can be remotely located up to 25' from the operator. The only connection between the control unit and the operator is a single flexible air pressure line. Multiple operators connected to a single control unit may require an increase in the size of the air line to the control unit.

SECURITY
Application of an electric strike or other systems which may be controlled by push buttons, key switches, or card key systems, proof of closure can be done without changes in the control unit.
* The Kwik-Op microprocessor controls the above cycles, and many other standard functions. Field programmable. Custom programs are available.

INSTALLATION
Rigid templates shall be provided for installation of operator, closer, and control unit. Specific instructions shall be provided for installation of all equipment supplied.
- It is not necessary to have factory trained installers.

ADJUSTMENT
- Speed of door opening, from 1.5 to 5 seconds, is governed by the air pressure adjustment knob in the control unit.
- Factory setting is 45 pounds.
- Opening/closing hold open time delay can be adjusted from 1 to 99 seconds using the adjustment screw on the time delay relay in the control unit. Factory setting is 10 seconds.
- Closer back check, opening/closing force, sweep speed, and latch speed and range are controlled by 4 adjustments on the outside of the closer.

- Factory shall maintain a toll free (800) telephone number, prominently displayed on the equipment, for factory direct service to the end user. Parts to user in 24hrs.

TO BE FURNISHED UNDER PLUMBING SECTION
AIR SUPPLY FOR AUTOMATIC DOOR OPERATORS
Air compressor sizing: 100/125 PSI range with sufficient capacity to furnish volume as follows: 1 double door operator requires 1 CFM, to be increased by .9 CFM for each additional double door installation.
- EXAMPLE: 6 double doors: minimum capacity 1 CFM plus 4.5 CFM = 5.5 CFM required. Specifications are available for compressor.

AIR SUPPLY LINES AND FITTINGS FOR AUTOMATIC DOOR
- Air supply lines to be of an adequate size for the volume required, (see above calculation), 1/2" minimum diameter, run from compressor to each control unit location and fitted with a pressure gauge, coalescing filter with automatic drain and shut off valve, then reduced to 1/4" dia. and terminate with a 1/4" NPTF female fitting (plugged until final connection is made).
- Terminus of line to be 5" to right of control unit centerline and 8" (minimum) above the control unit. Purge air supply prior to connecting to control unit or warranty may be voided.

TO BE FURNISHED UNDER ELECTRICAL SECTION
ELECTRICAL SUPPLY FOR AUTOMATIC DOOR OPERATORS
- Junction box (4") 110/120 VAC, 60 HZ, 2 AMP outlet to be furnished at each control unit location, 10" to left of control unit centerline and 6" (minimum) above the control unit. Wiring from activating switches or devices to control box to terminate at same junction box, (or per local code).

NOTE
Each installation requires analysis to insure proper performance of the opener system. A safety system should always be considered for pedestrian safety and protection. When a complete safety system is not used, the end user must have a safety meeting with their personnel to instruct them on the use of the automatic door system. This must be done as soon as the doors are put into operation.

RETROFITTING IN EXISTING CENTER HUNG DOOR INSTALLATIONS
CAM LIFT HINGE CONVERSION FOR AUTOMATIC DOOR OPERATORS
- When converting cam lift hinged door to automatic operation, the operator manufacturer shall provide a NO-RISE CONVERSION KIT with each operator, and a 4" wide steel filler tube or a fabricated structural channel.

As manufactured by:
Door Dynamics, Inc.

Architects... Call for Spec. Data Sheets.

5 YEAR WARRANTY
Door Dynamics Inc. Series DD 1000 and DD 2000 Automatic Door Operators are warranted against defects in material or workmanship for a period of five years from date of installation or a maximum of 62 months from the date of shipment when installed in accordance with installation instructions furnished by us. Warranty card must be executed and returned to us at the time of installation.

Our warranty does not cover defects due to improper installation, or failure to exercise normal maintenance. Defective Operator will be replaced at our option.